boiler oil ignition system technical specification

boiler oil ignition system technical specification

Instruction, Operation, and Maintenance Manual Boilers

2. (Option) - To insure total fuel independence, the main oil flame shall be ignited by a 10,000-Volt direct spark oil ignition system (available on C4-GO-30 and smaller burners). Fuel/Air Control System (Spec writer - select one of the following described systems 1 through 5). 1. On-Off Gas and Oil The main gas supply shall be controlled by a

Get a Quote

46 CFR § 62.35-20 - Oil-fired main boilers. | CFR | US Law

(2) Trial for ignition and ignition. (i) Only one burner per boiler is to be in trial for ignition at any time. (ii) Total boiler air flow during light off must be sufficient to prevent pocketing and explosive accumulations of combustible gases. (iii) The burner igniter must be in position and proven energized before admission of fuel to the boiler. The igniter must remain energized until the burner flame is …

Get a Quote

Boiler technical specification - ulrichkazan.hu

• Max. viscosity of fuel oil: 700 cSt. at 50 °C • Density of fuel oil: 991 kg/m3 at 15 °C • Turn down ratio on fuel oil: 3:1 • Max. HFO viscosity before and at HFO pump and preheater: 380 cSt. • Fuel oil viscosity at burner inlet: 14-16 cSt. • Fuel oil temperature at burner inlet: 135-148 °C

Get a Quote

How an Oil Burner Ignition System Works and How to

Instruction, Operation, and Maintenance Manual Boilers

Get a Quote

(PROJECT STANDARDS AND SPECIFICATIONS)

proper ignition and combustion. Burners are classified by the types of fuel fired, such as: oil, gas or a combination of gas and oil. A secondary consideration in classifying burners is the means by which combustion air is mixed with the fuel. Burner Management System - That portion of a boiler control system

Get a Quote

CE30 - BSE Sector | BPEC

May 11, 2018 · There are two primary components used for ignition systems – the ignition transformer and the solid state ignitor: Ignition Transformer – This is a step-up transformer that "steps up" an incoming voltage of 120 volts to 10,000. Solid State Ignitor – The solid state ignitor produces anywhere from 14,000-20,000 volts.

Get a Quote

Oil Fired Igniters, Pilots and Oil Guns for Power Plants

system typically required l Class 1, 2 or 3 igniters according to NFPA also available l Smoke free flame l Also available for marine diesel operation. Please request our detailed brochure on oil and dual fuel fired ignitors. Hegwein Oil Guns l Immediate light-up l Even spray pattern due to a special nozzle design proved in various applications

Get a Quote